As a world-class cultural tourism complex, the tourist resort in China sees a peak daily visitor flow of over 50,000, imposing extremely high requirements on the safety and stability of public drinking water supply. There are more than 120 public drinking water points across the resort, covering core visitor areas. Previously relying on ultraviolet mercury lamps for disinfection, the resort faced prominent pain points: long-term operation led to high energy consumption and the need for annual lamp replacement; moreover, the water temperature could rise to 50-60°C, posing a risk of scalding visitors. Plagued by these issues as well as traditional disinfection limitations—such as potential chemical residues (from auxiliary treatments), cumbersome maintenance, and unstable efficacy under high-flow conditions—the resort partnered with MASSPHOTON to adopt a customized UVC-LED water disinfection solution, achieving safe, continuous, and low-risk drinking water disinfection.
5000+
Peak daily visitor flow
120+
Public drinking water points
Contact Us
Email Our Engineers

We'll respond as soon aspossible(within 24 hours)

II. Core Challenges

High Visitor Flow

High visitor flow and drastic fluctuations in water demand, requiring the disinfection equipment to adapt to sudden water flow changes while maintaining stable disinfection efficiency.

Regulatory Compliance

Compliance with China’s National Drinking Water Hygiene Standard (GB 5749-2022), demanding a microbial sterilization rate of no less than 99.99% without chemical residues, adverse impact on water taste, or safety hazards like overheating.

Harsh Environment

Equipment installed in outdoor/semi-outdoor environments with high temperature, humidity, and dust, requiring long-term stable operation, minimal daily maintenance to control labor costs, and elimination of scald risks caused by water temperature rise.

Complex operation and maintenance

High energy consumption and frequent replacement costs of traditional ultraviolet mercury lamps—annual lamp replacement not only increased operational expenses but also disrupted normal service during maintenance.

资源-14x

III. Customized Solution

Leveraging the advantages of UVC-LED technology, MASSPHOTON developed a targeted solution:
资源-24x

1. Core Equipment:

Deployed MP-UVC-4LC modules (sterilization wavelength: 270-280nm). With a compact design, they seamlessly integrate into existing equipment for real-time flow-through disinfection. Unlike ultraviolet mercury lamps, the modules require no preheating and start instantly, eliminating water temperature rise and scald risks. They also feature waterproof and dustproof casings to adapt to outdoor conditions.

4LC
UVC LED Water Disinfection 1GPM
Module: MP-UVC-4LC

270-280nm wavelength

Inquire

2. Intelligent Control:

Vesta Home Co., Ltd. is committed to providing eco-friendly and innovative home products, emphasizing simple yet aesthetic design and environmentally friendly, comfortable natural materials to reduce environmental pollution in production.

资源 74x
Track
water flow
资源 64x
Disinfection
intensity
资源 54x
Automatic
alarms
资源 44x
Remote data
viewing
资源 34x
Maintenance
reminders

3. Installation & Integration:

Modular design enables quick installation without major modifications to existing water pipelines, minimizing operational disruption. The solution significantly saves energy compared to ultraviolet mercury lamps; additionally, the UVC-LED chips have a longer lifespan, extending the replacement cycle from 1 year (for mercury lamps) to 2 years, further reducing maintenance costs and operational downtime. No chemical reagents are needed, aligning with the resort’s environmental and cost-control goals.

Implementation Results

The solution has operated stably for 1 year, delivering remarkable outcomes:

Hygiene & Safety

99.99% sterilization rate, compliant with GB 5749-2022. No harmful substances /residues, no water temperature rise or scald risks.

Stable Operation

Zero service interruptions, adaptable to harsh outdoor conditions. Instant startup meets sudden water demand.

Cost & Energy Savings

30% energy reduction vs. traditional mercury lamps; 30% lower annual maintenance costs. 2-year lamp replacement cycle, UVC-LED lifespan ≥15,000 hours.

Positive Feedback

No related complaints. Effectively solves traditional mercury lamp pain points (overheating, high energy consumption, frequent maintenance) with low upkeep.

Project Significance & Application

This case fully verifies the solution’s reliability, safety, and cost-effectiveness in high-traffic public venues. Its core advantages—zero chemical residues, no water temperature rise, instant startup, high efficiency, stability, low energy consumption, and extended replacement cycle—make it applicable to theme parks, malls, hotels, stadiums, and office buildings, especially for public drinking water systems. It sets a benchmark in the cultural tourism industry for safe and efficient water disinfection, providing a valuable reference for public venues looking to upgrade their water safety protection systems while addressing the limitations of traditional ultraviolet mercury lamps.

Applicable Venues:
Theme Parks
Shopping Malls
Hotels
Stadiums
Office Buildings
Educational Institutions

Download Industry Cases

pdf

Industry Solution White Paper

Case Summary-MASSPHOTON UVC-LED Water Disinfection Solution

pdf

Industry Solution White Paper

Case Summary-MASSPHOTON UV-C Disinfection Solution for a CEA Indoor Farming Base

tonglanbeijingtu2

Get Touch With Us

Email Our Engineers

We'll respond as soon aspossible(within 24 hours)

blue-valves-releasing-clean-water-flowing-down-row-industrial-setting

CONTACT INFO

+852 2891 8655

info@massphoton.com

+852 4619 8806

Unit 542, 5/F, Building 5W, Phase One, Hong Kong Science Park

  +852 28918655
  info@massphoton.com
  Unit 542, 5/F, Building 5W, Phase One, Hong Kong Science Park

Newsletter

Stay up-to-date with our very latest news, technology and events.

Subscribe

Follow Us

Leave a Message
Email Our Engineers

We'll respond as soon aspossible(within 24 hours)

Copyright © 2025 MASSPHOTON LIMITED. All Rights Reserved.   Sitemap |   Privacy Policy